{"id":93770,"date":"2023-01-10T11:03:47","date_gmt":"2023-01-10T09:03:47","guid":{"rendered":"https:\/\/obera.fr\/conseils\/zone-atex-norme-atex-bases-protection-contre-risque-explosion\/"},"modified":"2025-05-06T08:50:17","modified_gmt":"2025-05-06T06:50:17","slug":"zone-atex-norme-atex-bases-protection-contre-risque-explosion","status":"publish","type":"post","link":"https:\/\/obera.fr\/da\/vores-raad\/zone-atex-norme-atex-bases-protection-contre-risque-explosion\/","title":{"rendered":"Hvordan hj\u00e6lper ATEX-standarder og -zoner med at forebygge risikoen for eksplosioner?"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>GRUNDL\u00c6GGENDE ATEX-DEFINITIONER<\/strong><\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\">HVAD ER ATEX-SYMBOLET?<\/h3>\n\n\n\n<p>Lidt forskellige betydninger afh\u00e6ngigt af det dokument, der l\u00e6ses:<\/p>\n\n\n\n<p><strong>ATEX<\/strong> = <strong>ATmosph\u00e8re EXplosive<\/strong> og ATEX = ATmosph\u00e8re Explosible = ATmosph\u00e8re potentiellement EXplosive<\/p>\n\n\n\n<p>Dette akronym, der stammer fra europ\u00e6iske direktiver, henviser til atmosf\u00e6ren i et arbejdsomr\u00e5de, hvor der er<strong> risiko for eksplosion<\/strong>, og som kr\u00e6ver s\u00e6rlige beskyttelsesstandarder for <strong>sikkerhed<\/strong> p\u00e5 arbejdspladsen. ATEX kan opst\u00e5 overalt: inde i maskiner eller tanke, arbejdsstationer, lagerbygninger osv. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Hvad er en<strong>eksplosiv atmosf\u00e6re?<\/strong><\/h3>\n\n\n\n<p>&#8220;Blanding med luft under atmosf\u00e6riske forhold af <strong>br\u00e6ndbare stoffer <\/strong>i form af gas, damp, t\u00e5ge eller st\u00f8v, hvor forbr\u00e6ndingen efter ant\u00e6ndelse breder sig til hele den uforbr\u00e6ndte blanding.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Hvad er en<strong>eksplosiv atmosf\u00e6re?<\/strong><\/h3>\n\n\n\n<p>&#8220;En atmosf\u00e6re, der kan blive eksplosiv som f\u00f8lge af lokale og driftsm\u00e6ssige forhold&#8221;. Selv om atmosf\u00e6ren best\u00e5r af br\u00e6ndbare stoffer, opfylder den ikke de betingelser, der placerer den i det <strong>eksplosive<\/strong> omr\u00e5de. <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/pictogramme_atex_4.png\" alt=\"atex 4-piktogram\" class=\"wp-image-19059\" width=\"225\" height=\"450\" srcset=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/pictogramme_atex_4.png 300w, https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/pictogramme_atex_4-150x300.png 150w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/figure>\n<\/div>\n<\/div>\n\n<h3 class=\"wp-block-heading\">Hvad er forskellen mellem et <strong>ATEX-direktiv og en ATEX-standard<\/strong>?<\/h3>\n\n<p>De <strong>europ\u00e6iske ATEX-direktiver<\/strong> udg\u00f8r en ramme for virksomhedernes juridiske ansvar. De p\u00e5l\u00e6gger <strong>sikkerhedsstandarder<\/strong> i zoner, hvor der er risiko for en eksplosiv atmosf\u00e6re. Bilagene til de europ\u00e6iske ATEX-direktiver indeholder en liste over de generelle beskyttelsesforanstaltninger, der er forbundet med ATEX. <strong>Europ\u00e6iske ATEX-standarder<\/strong> specificerer disse beskyttelses- og sikkerhedsforanstaltninger   <\/p>\n\n<p>De europ\u00e6iske ATEX-direktiver og -standarder er designet til at garantere sikkerheden for mennesker, udstyr og beskyttelsessystemer, der befinder sig i <strong>potentielt eksplosive atmosf\u00e6rer<\/strong>. ATEX-direktiverne og -standarderne er bindende for arbejdsgivere, producenter, installat\u00f8rer og andre. Kort sagt, enhver virksomhed, der bidrager til tilstedev\u00e6relsen af personale eller udstyr i en zone med eksplosiv atmosf\u00e6re. De kr\u00e6ver, at der tr\u00e6ffes forebyggende foranstaltninger, og at medarbejderne beskyttes i <strong>omr\u00e5der med eksplosionsrisiko <\/strong>(ATEX-zoner). <strong>ATEX-direktiver<\/strong> og <strong>-standarder<\/strong> definerer kategorien af udstyr, <a href=\"https:\/\/obera.fr\/conseils\/quelle-installation-daspiration-pour-mon-application\/\">installationer<\/a>, beskyttelsessystemer, beskyttelsesbekl\u00e6dning osv. i henhold til ATEX-risikozonen. De giver en ramme for overholdelse af en kategori af udstyr med det kr\u00e6vede beskyttelsesniveau.       <\/p>\n\n<p>En kategori af udstyr svarer til det risikoniveau, der findes i en kategori af zoner med eksplosiv atmosf\u00e6re. Standarderne skelner mellem forskellige niveauer af <strong>ATEX-overensstemmelsesvurderingsprocedurer<\/strong> for forskellige kategorier af udstyr, afh\u00e6ngigt af om det er elektrisk eller ikke-elektrisk. Afh\u00e6ngigt af det kravniveau, der er defineret i ATEX-direktiverne, er et notificeret ATEX-certificeringsorgan eller producenten autoriseret til at vurdere ATEX-udstyrets overensstemmelse. Endelig kr\u00e6ver ATEX-direktiverne, at arbejdsgivere udarbejder et <strong>eksplosionsbeskyttelsesdokument<\/strong> (EPD). Dette dokument formaliserer de foranstaltninger, der er truffet p\u00e5 arbejdspladsen mod risikoen for eksplosion.    <\/p>\n\n<h3 class=\"wp-block-heading\"><strong>Hvad er forskellen mellem ATEX-zoneinddeling og ATEX-zoner?<\/strong><\/h3>\n\n<p><strong>ATEX-zonering<\/strong> inddeler steder, hvor der kan forekomme eksplosive atmosf\u00e6rer, i 3 kategorier af ATEX-risikozoner (ATEX-zone).<\/p>\n\n<p>ATEX-zonekategorien er resultatet af en vurdering af niveauet for tilstedev\u00e6relsen af en <strong>eksplosiv<\/strong> atmosf\u00e6re for hvert sted. En <strong>ATEX-zonekategori<\/strong> svarer til et <strong>ATEX-risikofrekvensniveau<\/strong>. ATEX-zonekategorien p\u00e5virker arten af de organisatoriske og tekniske foranstaltninger, der skal tr\u00e6ffes i forbindelse med tilstedev\u00e6relsen af ATEX. ATEX-standarder definerer de foranstaltninger, der g\u00e6lder, afh\u00e6ngigt af ATEX-zonekategorien, for <strong>udstyrssikkerhed<\/strong> og beskyttelse af arbejdstagere. Disse ATEX-standarder tilskynder is\u00e6r til <strong>eliminering af den eksplosive atmosf\u00e6re i disse zoner<\/strong>, hvis ikke for at reducere risikoen for eksplosion, og endelig for at beskytte mennesker og udstyr, hvis <a href=\"https:\/\/obera.fr\/conseils\/aspiration-brouillard-huile-emulsion-quel-danger-fluides-coupe\/\">risikoen<\/a> for eksplosion materialiserer sig i en zone. ATEX-zoneinddeling angiver den kategori af<strong>ATEX-udstyr<\/strong> og ATEX-beskyttelsessystemer, der er godkendt i en ATEX-zonekategori. ATEX-m\u00e6rkningen angiver, at udstyret er blevet vurderet og har et passende beskyttelsesniveau i forhold til den eksplosionsrisiko, der er identificeret i ATEX-zonen.      <\/p>\n\n<h2 class=\"wp-block-heading\">ATEX-zonekategorier<\/h2>\n\n<table id=\"tablepress-180\" class=\"tablepress tablepress-id-180\">\n<thead>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><th class=\"column-2\">Atmosph\u00e8re explosive compos\u00e9e d\u2019un m\u00e9lange :<\/th><td class=\"column-3\"><\/td>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Risque d\u2019explosion ATEX<\/td><td class=\"column-2\">air -gaz \/vapeur ou brouillard inflammables<\/td><td class=\"column-3\">air - poussi\u00e8res combustibles<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Permanent<\/td><td class=\"column-2\">Zone ATEX 0<\/td><td class=\"column-3\">Zone ATEX 20<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Occasionnel<\/td><td class=\"column-2\">Zone ATEX 1<\/td><td class=\"column-3\">Zone ATEX 21<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Potentiel<\/td><td class=\"column-2\">Zone ATEX 2<\/td><td class=\"column-3\">Zone ATEX 22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h2 class=\"wp-block-heading\"><br\/>ATEX-zone, hvor brandfarligt st\u00f8v udg\u00f8r den eksplosive atmosf\u00e6re<\/h2>\n\n<table id=\"tablepress-181\" class=\"tablepress tablepress-id-181\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Fonctionnement mat\u00e9riel ATEX<\/th><th class=\"column-2\">Pr\u00e9sence d\u2019ATEX<br \/>\n<br \/>\n<\/th><th class=\"column-3\">Lieu d\u2019ATEX<\/th><th class=\"column-4\">Cat\u00e9gorie de zone ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">permanente<br \/>\n<br \/>\nlongue dur\u00e9e<br \/>\n<br \/>\nfr\u00e9quente<\/td><td class=\"column-3\"><br \/>\nInt\u00e9rieur d\u2019installations, \u00e9quipements (d\u00e9poussi\u00e9reurs, filtres, collecteurs de poussi\u00e8res\u2026)<br \/>\n<\/td><td class=\"column-4\">Zone ATEX 20<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">occasionnelle<\/td><td class=\"column-3\">Proximit\u00e9 imm\u00e9diate de zone ATEX 20<br \/>\nPoints de remplissage \/ vidange (produits pulv\u00e9rulents)<\/td><td class=\"column-4\">Zone ATEX 21<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">anormal<\/td><td class=\"column-2\">accidentelle<\/td><td class=\"column-3\">Voisinage d\u2019appareils, syst\u00e8mes de protection contenant de la poussi\u00e8re pouvant s\u2019\u00e9chapper accidentellement en nuage de poussi\u00e8res<br \/>\nCouches, d\u00e9p\u00f4ts, tas de poussi\u00e8res combustibles susceptibles de former une atmosph\u00e8re explosive (surfaces impossibles \u00e0 aspirer\u2026)<\/td><td class=\"column-4\">Zone ATEX 22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h2 class=\"wp-block-heading\">ATEX-zone, hvor brandfarlige gasser, dampe eller t\u00e5ger udg\u00f8r den eksplosive atmosf\u00e6re<\/h2>\n\n<table id=\"tablepress-182\" class=\"tablepress tablepress-id-182\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Fonctionnement mat\u00e9riel ATEX<\/th><th class=\"column-2\">Pr\u00e9sence d\u2019ATEX<\/th><th class=\"column-3\">Lieu d\u2019ATEX<\/th><th class=\"column-4\">Cat\u00e9gorie de zone \u00e0 risque ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">permanente <br \/>\n<br \/>\nde longue dur\u00e9e <br \/>\n<br \/>\nfr\u00e9quente<\/td><td class=\"column-3\">Int\u00e9rieur conteneurs de gaz inflammables, liquides inflammables\/combustibles.<br \/>\ncanalisations,<br \/>\nr\u00e9servoirs,<br \/>\nr\u00e9cipients<br \/>\n<\/td><td class=\"column-4\">Zone ATEX 20<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">occasionnelle<\/td><td class=\"column-3\">Proximit\u00e9 imm\u00e9diate zone 0<br \/>\nProximit\u00e9 imm\u00e9diate des ouvertures du mat\u00e9riel :<br \/>\nouvertures d\u2019alimentation, \u00e9vents, vannes de prise d\u2019\u00e9chantillons \/de purge, ouvertures de remplissage \/vidange<br \/>\nPoints bas des installations : fosses de r\u00e9tention, caniveaux<\/td><td class=\"column-4\">Zone ATEX 21<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">anormal<\/td><td class=\"column-2\">accidentelle<\/td><td class=\"column-3\">Emplacements autour des zones 0 et 1,<br \/>\nBrides, connexions, vannes et raccords (tuyauterie)<br \/>\nCuvettes de r\u00e9tention<br \/>\nProximit\u00e9 imm\u00e9diate des tubes de niveau en verre, appareils en mat\u00e9riaux fragiles, tout appareil ou \u00e9l\u00e9ment susceptible de fuites<br \/>\n<\/td><td class=\"column-4\">Zone ATEX 22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h2 class=\"wp-block-heading\">FRA \u00c5RSAGERNE TIL ATEXDANNELSE TIL KONSEKVENSERNE AF EN EKSPLOSION<\/h2>\n\n<h3 class=\"wp-block-heading\">Hvad er betingelserne for dannelsen af en ATEX?<\/h3>\n\n<p><strong>Tilstedev\u00e6relsen af br\u00e6ndbare<\/strong> stoffer (gas, damp, st\u00f8v), der blander sig med atmosf\u00e6ren i zonen, udg\u00f8r <strong>begyndelsen p\u00e5 eksplosionsrisikoen<\/strong>. Den omgivende luft\/br\u00e6ndbare produktblanding bliver en ATEX, hvis den opfylder de fysisk-kemiske standarder, der er forbundet med eksplosionsrisikoen. Jo mere homogen luft\/produkt-blandingen er, jo mere<strong>eksplosiv er atmosf\u00e6ren<\/strong>. Disse forhold \u00f8ger eksplosionsrisikoen uden at for\u00e5rsage en eksplosion i ATEX-zonen.   <\/p>\n\n<table id=\"tablepress-183\" class=\"tablepress tablepress-id-183\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">ATEX : mati\u00e8re inflammable:<\/th><th class=\"column-2\">Condition minimale de formation d\u2019ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">gaz<\/td><td class=\"column-2\">Concentration du gaz dans l\u2019air suffisante pour que le risque d\u2019explosion du m\u00e9lange se concr\u00e9tise si une source d\u2019inflammation apparait<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">vapeur \u00e9mise par un liquide<\/td><td class=\"column-2\">Temp\u00e9rature du liquide suscitant un d\u00e9gagement de vapeurs suffisant pour que la concentration de vapeurs dans l\u2019air atteigne la plage d\u2019explosibilit\u00e9<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">poussi\u00e8re en nuage<\/td><td class=\"column-2\">Niveau de concentration des poussi\u00e8res en suspension dans l\u2019air suffisant pour provoquer sous conditions une explosion<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h3 class=\"wp-block-heading\">Hvad er ant\u00e6ndelseskilderne i en ATEX?<\/h3>\n\n<p><strong>Ant\u00e6ndelseskilden<\/strong> bringer den energi ind i ATEX-zonen, som udl\u00f8ser forbr\u00e6ndingsreaktionen mellem den omgivende luft og br\u00e6ndstoffet. Denne betingelse, som er n\u00f8dvendig for, at<strong>ATEX<\/strong> kan<strong>ant\u00e6ndes<\/strong>, \u00f8ger eksplosionsrisikoen i zonen, men er ikke i sig selv tilstr\u00e6kkelig til at frembringe en eksplosion. Eksempel: En t\u00e6ndstik f\u00e5r den brandfarlige luft\/butan-blanding i et gaskomfur til at ant\u00e6nde uden at eksplodere.  <\/p>\n\n<table id=\"tablepress-184\" class=\"tablepress tablepress-id-184\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Origine des sources d\u2019inflammation<\/th><th class=\"column-2\">Nature des sources d\u2019inflammation ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Electrique<\/td><td class=\"column-2\">\u00e9tincelle (arc \u00e9lectrique, courant \u00e9lectrique vagabond, \u2026<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">\u00c9lectrostatique<\/td><td class=\"column-2\">\u00e9tincelle (d\u00e9charge \u00e9lectrostatique), foudre, \u2026<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">M\u00e9canique<\/td><td class=\"column-2\">\u00e9tincelle (particules incandescentes), \u00e9chauffement par friction, \u2026<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Thermique<\/td><td class=\"column-2\">surfaces chaudes, flammes nues, travaux par points chauds, cigarettes, rayonnement solaire\u2026<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Chimique<\/td><td class=\"column-2\">r\u00e9actions exothermiques (auto-\u00e9chauffement, \u00e9chauffement par fermentation \u2026)<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Autres<\/td><td class=\"column-2\">rayonnement ionisant, ondes \u00e9lectromagn\u00e9tiques, ultrasons, \u2026<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<p>En zone er udstyret med forskelligt udstyr, der genererer <strong>ATEX-ant\u00e6ndelseskilder<\/strong>. Til validering af ATEX-overholdelse skelner de <a href=\"https:\/\/a2s-atex.com\/fr\/content\/11-les-directives-europeennes-atex\">europ\u00e6iske ATEX-regler<\/a> mellem 2 kategorier af udstyr (elektrisk udstyr og ikke-elektrisk udstyr), afh\u00e6ngigt af den kategori af ATEX-zone, der skal udstyres. <\/p>\n\n<h3 class=\"wp-block-heading\">Hvad er betingelserne for en eksplosion i en ATEX-zone?<\/h3>\n\n<p>En ATEX-eksplosion udl\u00f8ses, n\u00e5r 6 forhold indtr\u00e6ffer samtidigt.<\/p>\n\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>3 elementer i tilstr\u00e6kkelig m\u00e6ngde til at <strong>ant\u00e6nde ATEX<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Br\u00e6ndbart produkt<\/strong> (gas, damp, st\u00f8v) til stede i atmosf\u00e6ren i omr\u00e5det<\/li>\n\n\n\n<li><strong>Forbr\u00e6ndingsmiddel<\/strong> (ilt fra atmosf\u00e6ren), der stimulerer forbr\u00e6ndingen af det br\u00e6ndstof, der er til stede i zonens atmosf\u00e6re<\/li>\n\n\n\n<li><strong>Ant\u00e6ndelseskilde<\/strong> (f.eks. elektrisk gnist), der giver tilstr\u00e6kkelig energi til at ant\u00e6nde den eksplosive atmosf\u00e6re.<\/li>\n<\/ol>\n\n\n\n<p>3 forbr\u00e6ndingsacceleratorer til at forvandle ant\u00e6ndelse til eksplosion<\/p>\n\n\n\n<ol class=\"wp-block-list\" start=\"4\">\n<li>Homogen iltblanding &#8211; br\u00e6ndbart produkt (gas\/damp\/st\u00f8v) i eksplosiv atmosf\u00e6re<\/li>\n\n\n\n<li>I ATEX er koncentrationen af det br\u00e6ndbare produkt inden for det eksplosive omr\u00e5de.<\/li>\n\n\n\n<li>Tilstr\u00e6kkelig indeslutning til at opn\u00e5 det <strong>rette tryk<\/strong> til at fremskynde forbr\u00e6ndingen<\/li>\n<\/ol>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/conditions-dexplosition-atex.png\" alt=\"atex driftsbetingelser\" class=\"wp-image-19050\" width=\"350\" height=\"300\" srcset=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/conditions-dexplosition-atex.png 350w, https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/conditions-dexplosition-atex-300x257.png 300w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/figure>\n<\/div>\n<\/div>\n\n<h3 class=\"wp-block-heading\">Hvad er mekanismen bag en ATEX-eksplosion?<\/h3>\n\n<p>En ATEX kommer i kontakt med en ant\u00e6ndelseskilde. En<strong>eksplosion udl\u00f8ses<\/strong>: \u00f8jeblikkelig forbr\u00e6nding af de br\u00e6ndbare produkter i ATEX&#8217;en, hvilket frigiver intens energi. Eksplosionen har form af en<strong>pludselig stigning i volumen, tryk og temperatur af gasserne<\/strong> i ATEX&#8217;en. Det skaber en overtryksb\u00f8lge, der udbreder sig med en hastighed p\u00e5 2 til 10 km\/s (eksplosionseffekt), flammer og varmeudvikling. En del af eksplosionsb\u00f8lgens energi splintrer kontaktfladen eller den indkapsling, som den eksplosive atmosf\u00e6re var indesluttet i, hvorefter fragmenter af det splintrede materiale slynges ud.    <\/p>\n\n<p><strong>Eksplosionsb\u00f8lgen<\/strong> bev\u00e6ger sig derefter i koncentriske zoner med supersonisk hastighed; den falder derefter gradvist i to faser: en tid med overtryk (1 til 5 millisekunder) og en <strong>tid<\/strong> med undertryk (sug), indtil den vender tilbage til <strong>normalt atmosf\u00e6risk tryk<\/strong> (5 til 25 ms). Eksplosionsb\u00f8lgen aftager med afstanden og graden af indeslutning af atmosf\u00e6ren i arbejdsomr\u00e5det. Reduktionen er: meget lille, n\u00e5r eksplosionsb\u00f8lgen udbreder sig langs en enkelt akse (forbindelseskanal mellem udstyr osv.), hurtigere ved 2-dimensionel udbredelse (lokaler osv.), meget hurtig i et \u00e5bent milj\u00f8 (udstyr uden for lokalerne osv.). Beskyttelsessystemer begr\u00e6nser eksplosionen p\u00e5 forskellige m\u00e5der: udluftning, afkoblingssystemer osv.   <\/p>\n\n<h3 class=\"wp-block-heading\">Hvilke risici er der forbundet med ATEX-eksplosioner?<\/h3>\n\n<h4 class=\"wp-block-heading\">ATEX-eksplosionsrisici for medarbejdernes sikkerhed.<\/h4>\n\n<p>Risikoen for arbejdere i tilf\u00e6lde af en ATEX-eksplosion danner grundlag for regler om deres beskyttelse og sikkerhed. <strong>Risikoen for skader<\/strong> varierer alt efter den zone, hvor arbejderen er udsat for eksplosionsfare. <\/p>\n\n<h4 class=\"wp-block-heading\">Risiko for skader fra eksplosion :<\/h4>\n\n<ul class=\"wp-block-list\">\n<li>risici p\u00e5 grund af<strong>eksplosionsb\u00f8lgen<\/strong>, der rammer hule eller gasfyldte dele af kroppen<\/li>\n\n\n\n<li>risici forbundet med<strong>virkningen af forventede fragmenter<\/strong> af eksploderede anl\u00e6g eller udstyr,<\/li>\n\n\n\n<li>risiko for, at medarbejderen bliver kastet af eksplosionsb\u00f8lgen<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">Risici for skader i forbindelse med ATEX-eksplosionens indvirkning p\u00e5 installationer, udstyr, materialer osv:<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>risiko for forbr\u00e6ndinger, knusning, ind\u00e5nding af giftstoffer<\/strong>; konsekvenser af \u00f8del\u00e6ggelse og ant\u00e6ndelse for\u00e5rsaget af eksplosionen<\/li>\n\n\n\n<li>risici for <strong>immun- og nervesystemet <\/strong>gennem optagelse af giftige stoffer<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">ATEX-eksplosionsrisici for udstyr.<\/h4>\n\n<p>Eksplosionsb\u00f8lgen og ant\u00e6ndelsen af atmosf\u00e6ren skaber virkninger p\u00e5 udstyret. Eksplosionen kan <strong>for\u00e5rsage fragmentering af kildeenheden<\/strong>, tilstedev\u00e6relsen af et krater ved eksplosionens epicenter, projektion af fragmenter af materiale, der gennemsyrer udstyret eller infrastrukturen, projektion af ant\u00e6ndte materialer, der er kilder til yderligere ant\u00e6ndelser eller eksplosioner (dominoeffekt) osv. <\/p>\n\n<p>N\u00e5r risikoen for en ATEX-eksplosion er blevet vurderet, skal arbejdsgiveren tr\u00e6ffe forskellige foranstaltninger for at <strong>sikre sikkerhed<\/strong> og beskyttelse af medarbejdere og udstyr: DRPCE, <strong>beskyttelsessystemer og -t\u00f8j<\/strong>, ATEX-udstyr osv.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dette akronym, der stammer fra europ\u00e6iske direktiver, henviser til atmosf\u00e6ren i et arbejdsomr\u00e5de, hvor der er risiko for eksplosion, og som kr\u00e6ver s\u00e6rlige beskyttelsesstandarder for sikkerhed p\u00e5 arbejdspladsen. ATEX kan opst\u00e5 overalt: inde i maskiner eller tanke, arbejdsstationer, lagerbygninger osv. <\/p>\n","protected":false},"author":4,"featured_media":93612,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Hvordan hj\u00e6lper ATEX-standarder med at forhindre eksplosioner?","_seopress_titles_desc":"I denne artikel finder du alt det grundl\u00e6ggende, du har brug for at vide, hvis du arbejder i en ATEX-zone, hvor der er risiko for eksplosion.","_seopress_robots_index":"","footnotes":""},"categories":[295],"tags":[303],"class_list":["post-93770","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vores-raad","tag-entete-lille","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","no-featured-image-padding","resize-featured-image"],"acf":[],"_links":{"self":[{"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/posts\/93770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/comments?post=93770"}],"version-history":[{"count":1,"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/posts\/93770\/revisions"}],"predecessor-version":[{"id":93777,"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/posts\/93770\/revisions\/93777"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/media\/93612"}],"wp:attachment":[{"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/media?parent=93770"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/categories?post=93770"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/obera.fr\/da\/wp-json\/wp\/v2\/tags?post=93770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}