{"id":93678,"date":"2023-01-10T11:03:47","date_gmt":"2023-01-10T09:03:47","guid":{"rendered":"https:\/\/obera.fr\/geen-onderdeel-van-een-categorie\/zone-atex-norme-atex-bases-protection-contre-risque-explosion\/"},"modified":"2025-05-06T08:43:32","modified_gmt":"2025-05-06T06:43:32","slug":"zone-atex-norme-atex-bases-protection-contre-risque-explosion","status":"publish","type":"post","link":"https:\/\/obera.fr\/nl\/ons-advies\/zone-atex-norme-atex-bases-protection-contre-risque-explosion\/","title":{"rendered":"Hoe helpen ATEX-normen en -zones om explosiegevaar te voorkomen?"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>ATEX-BASISDEFINITIES<\/strong><\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\">WAT IS HET ATEX-SYMBOOL?<\/h3>\n\n\n\n<p>Verschillende betekenissen afhankelijk van het document dat wordt gelezen:<\/p>\n\n\n\n<p><strong>ATEX<\/strong> = <strong>ATmosph\u00e8re EXplosive<\/strong> en ATEX = ATmosph\u00e8re Explosible = ATmosph\u00e8re potentiellement EXplosive<\/p>\n\n\n\n<p>Dit acroniem, afgeleid van Europese richtlijnen, verwijst naar de atmosfeer in een werkgebied waar<strong> explosiegevaar<\/strong> bestaat en waar speciale beschermingsnormen nodig zijn voor <strong>de veiligheid op het werk<\/strong>. ATEX kan overal voorkomen: binnenin machines of tanks, werkstations, magazijnen, enz. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Wat is<strong>een explosieve atmosfeer?<\/strong><\/h3>\n\n\n\n<p>&#8220;Het mengsel met lucht, onder atmosferische omstandigheden, van <strong>brandbare stoffen <\/strong>in de vorm van gas, damp, nevel of stof, waarin, na ontsteking, de verbranding zich uitbreidt tot het gehele niet verbrande mengsel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Wat is<strong>een explosieve atmosfeer?<\/strong><\/h3>\n\n\n\n<p>&#8220;Een atmosfeer die explosief kan worden als gevolg van plaatselijke en bedrijfsomstandigheden&#8221;. De atmosfeer, ook al bestaat deze uit brandbare stoffen, voldoet niet aan de voorwaarden die hem in zijn <strong>explosieve bereik<\/strong> plaatsen. <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/pictogramme_atex_4.png\" alt=\"atex 4 pictogram\" class=\"wp-image-19059\" width=\"225\" height=\"450\" srcset=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/pictogramme_atex_4.png 300w, https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/pictogramme_atex_4-150x300.png 150w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/figure>\n<\/div>\n<\/div>\n\n<h3 class=\"wp-block-heading\">Wat is het verschil tussen een <strong>ATEX-richtlijn en een ATEX-norm?<\/strong><\/h3>\n\n<p>De <strong>Europese ATEX-richtlijnen<\/strong> bieden een kader voor de wettelijke verantwoordelijkheid van bedrijven. Ze leggen <strong>veiligheidsnormen<\/strong> op in zones waar een explosieve atmosfeer kan voorkomen. In de bijlagen van de Europese ATEX-richtlijnen staan de algemene beschermingsmaatregelen die bij ATEX horen. <strong>De Europese ATEX-normen<\/strong> specificeren deze beschermings- en veiligheidsmaatregelen   <\/p>\n\n<p>De Europese ATEX-richtlijnen en -normen zijn ontworpen om de veiligheid te garanderen van mensen, apparatuur en beveiligingssystemen die zich in <strong>een potentieel explosieve omgeving<\/strong> bevinden. De ATEX-richtlijnen en -normen zijn bindend voor werkgevers, fabrikanten, installateurs en anderen. Kortom, elk bedrijf dat bijdraagt aan de aanwezigheid van personeel of apparatuur in een zone met een explosieve atmosfeer. Ze vereisen dat er preventieve maatregelen worden genomen en dat werknemers worden beschermd in <strong>gebieden met explosiegevaar <\/strong>(ATEX-zones). <strong>ATEX-richtlijnen<\/strong> en <strong>-normen<\/strong> defini\u00ebren de categorie van apparatuur, <a href=\"https:\/\/obera.fr\/conseils\/quelle-installation-daspiration-pour-mon-application\/\">installaties<\/a>, beschermingssystemen, beschermende kleding, enz. op basis van de ATEX-risicozone. Ze bieden een kader voor de conformiteit van een categorie apparaten met het vereiste beschermingsniveau.       <\/p>\n\n<p>Een categorie van apparatuur komt overeen met het risiconiveau dat bestaat in een categorie van zone met explosieve atmosfeer. De normen maken onderscheid tussen verschillende niveaus van <strong>ATEX-conformiteitsbeoordelingsprocedures<\/strong> voor verschillende categorie\u00ebn apparatuur, afhankelijk van het feit of het elektrisch of niet-elektrisch is. Afhankelijk van het niveau van de vereisten die door de ATEX-richtlijnen zijn gedefinieerd, is een aangemelde ATEX-certificeringsinstantie of de fabrikant bevoegd om de conformiteit van ATEX-apparatuur te beoordelen. Tot slot verplichten de ATEX-richtlijnen werkgevers om een <strong>explosieveiligheidsdocument<\/strong> (EPD) op te stellen. Dit document formaliseert de maatregelen die op de werkplek zijn genomen tegen explosiegevaar.    <\/p>\n\n<h3 class=\"wp-block-heading\"><strong>Wat is het verschil tussen ATEX-zonering en ATEX-zones?<\/strong><\/h3>\n\n<p><strong>ATEX-zonering<\/strong> verdeelt locaties waar explosieve atmosferen kunnen voorkomen in 3 categorie\u00ebn van ATEX-risicozones (ATEX Zone).<\/p>\n\n<p>De ATEX Zone categorie is het resultaat van een beoordeling van de mate van aanwezigheid van een <strong>explosieve<\/strong> atmosfeer voor elke locatie. Een <strong>ATEX Zonecategorie<\/strong> komt overeen met een <strong>ATEX-risicofrequentieniveau<\/strong>. De ATEX-zonecategorie is van invloed op de aard van de organisatorische en technische maatregelen die bij aanwezigheid van ATEX moeten worden genomen. ATEX-normen defini\u00ebren de maatregelen die, afhankelijk van de ATEX Zonecategorie, van toepassing zijn op <strong>de veiligheid van apparatuur<\/strong> en de bescherming van werknemers. Deze ATEX-normen stimuleren in het bijzonder de <strong>eliminatie van de explosieve atmosfeer in deze zones<\/strong>, zo niet om het explosiegevaar te verminderen, en ten slotte om mensen en apparatuur te beschermen als het <a href=\"https:\/\/obera.fr\/conseils\/aspiration-brouillard-huile-emulsion-quel-danger-fluides-coupe\/\">explosiegevaar<\/a> zich in een zone voordoet. ATEX-zonering geeft de categorie<strong>ATEX-apparatuur<\/strong> en ATEX-beschermingssystemen aan die in een ATEX-zone zijn toegestaan. De ATEX-markering geeft aan dat de apparatuur is beoordeeld en het juiste beschermingsniveau heeft voor het explosierisico dat in de ATEX-zone is vastgesteld.      <\/p>\n\n<h2 class=\"wp-block-heading\">ATEX-zonecategorie\u00ebn<\/h2>\n\n<table id=\"tablepress-180\" class=\"tablepress tablepress-id-180\">\n<thead>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><th class=\"column-2\">Atmosph\u00e8re explosive compos\u00e9e d\u2019un m\u00e9lange :<\/th><td class=\"column-3\"><\/td>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Risque d\u2019explosion ATEX<\/td><td class=\"column-2\">air -gaz \/vapeur ou brouillard inflammables<\/td><td class=\"column-3\">air - poussi\u00e8res combustibles<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Permanent<\/td><td class=\"column-2\">Zone ATEX 0<\/td><td class=\"column-3\">Zone ATEX 20<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Occasionnel<\/td><td class=\"column-2\">Zone ATEX 1<\/td><td class=\"column-3\">Zone ATEX 21<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Potentiel<\/td><td class=\"column-2\">Zone ATEX 2<\/td><td class=\"column-3\">Zone ATEX 22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h2 class=\"wp-block-heading\"><br\/>ATEX-zone waar brandbaar stof de explosieve atmosfeer vormt<\/h2>\n\n<table id=\"tablepress-181\" class=\"tablepress tablepress-id-181\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Fonctionnement mat\u00e9riel ATEX<\/th><th class=\"column-2\">Pr\u00e9sence d\u2019ATEX<br \/>\n<br \/>\n<\/th><th class=\"column-3\">Lieu d\u2019ATEX<\/th><th class=\"column-4\">Cat\u00e9gorie de zone ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">permanente<br \/>\n<br \/>\nlongue dur\u00e9e<br \/>\n<br \/>\nfr\u00e9quente<\/td><td class=\"column-3\"><br \/>\nInt\u00e9rieur d\u2019installations, \u00e9quipements (d\u00e9poussi\u00e9reurs, filtres, collecteurs de poussi\u00e8res\u2026)<br \/>\n<\/td><td class=\"column-4\">Zone ATEX 20<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">occasionnelle<\/td><td class=\"column-3\">Proximit\u00e9 imm\u00e9diate de zone ATEX 20<br \/>\nPoints de remplissage \/ vidange (produits pulv\u00e9rulents)<\/td><td class=\"column-4\">Zone ATEX 21<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">anormal<\/td><td class=\"column-2\">accidentelle<\/td><td class=\"column-3\">Voisinage d\u2019appareils, syst\u00e8mes de protection contenant de la poussi\u00e8re pouvant s\u2019\u00e9chapper accidentellement en nuage de poussi\u00e8res<br \/>\nCouches, d\u00e9p\u00f4ts, tas de poussi\u00e8res combustibles susceptibles de former une atmosph\u00e8re explosive (surfaces impossibles \u00e0 aspirer\u2026)<\/td><td class=\"column-4\">Zone ATEX 22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h2 class=\"wp-block-heading\">ATEX-zone waar ontvlambare gassen, dampen of nevels de explosieve atmosfeer vormen<\/h2>\n\n<table id=\"tablepress-182\" class=\"tablepress tablepress-id-182\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Fonctionnement mat\u00e9riel ATEX<\/th><th class=\"column-2\">Pr\u00e9sence d\u2019ATEX<\/th><th class=\"column-3\">Lieu d\u2019ATEX<\/th><th class=\"column-4\">Cat\u00e9gorie de zone \u00e0 risque ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">permanente <br \/>\n<br \/>\nde longue dur\u00e9e <br \/>\n<br \/>\nfr\u00e9quente<\/td><td class=\"column-3\">Int\u00e9rieur conteneurs de gaz inflammables, liquides inflammables\/combustibles.<br \/>\ncanalisations,<br \/>\nr\u00e9servoirs,<br \/>\nr\u00e9cipients<br \/>\n<\/td><td class=\"column-4\">Zone ATEX 20<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">normal<\/td><td class=\"column-2\">occasionnelle<\/td><td class=\"column-3\">Proximit\u00e9 imm\u00e9diate zone 0<br \/>\nProximit\u00e9 imm\u00e9diate des ouvertures du mat\u00e9riel :<br \/>\nouvertures d\u2019alimentation, \u00e9vents, vannes de prise d\u2019\u00e9chantillons \/de purge, ouvertures de remplissage \/vidange<br \/>\nPoints bas des installations : fosses de r\u00e9tention, caniveaux<\/td><td class=\"column-4\">Zone ATEX 21<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">anormal<\/td><td class=\"column-2\">accidentelle<\/td><td class=\"column-3\">Emplacements autour des zones 0 et 1,<br \/>\nBrides, connexions, vannes et raccords (tuyauterie)<br \/>\nCuvettes de r\u00e9tention<br \/>\nProximit\u00e9 imm\u00e9diate des tubes de niveau en verre, appareils en mat\u00e9riaux fragiles, tout appareil ou \u00e9l\u00e9ment susceptible de fuites<br \/>\n<\/td><td class=\"column-4\">Zone ATEX 22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h2 class=\"wp-block-heading\">VAN DE OORZAKEN VAN ATEXVORMING TOT DE GEVOLGEN VAN EEN EXPLOSIE<\/h2>\n\n<h3 class=\"wp-block-heading\">Wat zijn de voorwaarden voor het ontstaan van een ATEX?<\/h3>\n\n<p>De <strong>aanwezigheid van brandbare stoffen<\/strong> (gas, damp, stof) die zich mengen met de atmosfeer in de zone, vormt het <strong>begin van explosiegevaar<\/strong>. Het mengsel van omgevingslucht en brandbaar product wordt ATEX als het voldoet aan de fysisch-chemische normen in verband met explosiegevaar. Hoe homogener het lucht\/productmengsel, hoe<strong>explosiever de atmosfeer<\/strong>. Deze omstandigheden verhogen het explosiegevaar, zonder een explosie in de ATEX-zone te veroorzaken.   <\/p>\n\n<table id=\"tablepress-183\" class=\"tablepress tablepress-id-183\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">ATEX : mati\u00e8re inflammable:<\/th><th class=\"column-2\">Condition minimale de formation d\u2019ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">gaz<\/td><td class=\"column-2\">Concentration du gaz dans l\u2019air suffisante pour que le risque d\u2019explosion du m\u00e9lange se concr\u00e9tise si une source d\u2019inflammation apparait<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">vapeur \u00e9mise par un liquide<\/td><td class=\"column-2\">Temp\u00e9rature du liquide suscitant un d\u00e9gagement de vapeurs suffisant pour que la concentration de vapeurs dans l\u2019air atteigne la plage d\u2019explosibilit\u00e9<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">poussi\u00e8re en nuage<\/td><td class=\"column-2\">Niveau de concentration des poussi\u00e8res en suspension dans l\u2019air suffisant pour provoquer sous conditions une explosion<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h3 class=\"wp-block-heading\">Wat zijn de ontstekingsbronnen van een ATEX?<\/h3>\n\n<p>De <strong>ontstekingsbron<\/strong> brengt de energie in de ATEX-zone die de verbrandingsreactie tussen de omgevingslucht en de brandstof op gang brengt. Deze voorwaarde, die noodzakelijk is om de<strong>ATEX te laten ontbranden<\/strong>, verhoogt het explosiegevaar in de zone, maar is op zichzelf niet voldoende om een explosie te veroorzaken. Voorbeeld: een lucifer zorgt ervoor dat het brandbare lucht\/butaanmengsel in een gasfornuis ontbrandt zonder te exploderen.  <\/p>\n\n<table id=\"tablepress-184\" class=\"tablepress tablepress-id-184\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Origine des sources d\u2019inflammation<\/th><th class=\"column-2\">Nature des sources d\u2019inflammation ATEX<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Electrique<\/td><td class=\"column-2\">\u00e9tincelle (arc \u00e9lectrique, courant \u00e9lectrique vagabond, \u2026<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">\u00c9lectrostatique<\/td><td class=\"column-2\">\u00e9tincelle (d\u00e9charge \u00e9lectrostatique), foudre, \u2026<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">M\u00e9canique<\/td><td class=\"column-2\">\u00e9tincelle (particules incandescentes), \u00e9chauffement par friction, \u2026<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Thermique<\/td><td class=\"column-2\">surfaces chaudes, flammes nues, travaux par points chauds, cigarettes, rayonnement solaire\u2026<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Chimique<\/td><td class=\"column-2\">r\u00e9actions exothermiques (auto-\u00e9chauffement, \u00e9chauffement par fermentation \u2026)<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Autres<\/td><td class=\"column-2\">rayonnement ionisant, ondes \u00e9lectromagn\u00e9tiques, ultrasons, \u2026<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<p>Een zone is uitgerust met een verscheidenheid aan apparatuur die <strong>ATEXontstekingsbronnen<\/strong> genereert. Voor de validatie van ATEX-conformiteit, afhankelijk van de categorie ATEX-zone die moet worden uitgerust, maken <a href=\"https:\/\/a2s-atex.com\/fr\/content\/11-les-directives-europeennes-atex\">de Europese ATEX-voorschriften<\/a> onderscheid tussen 2 categorie\u00ebn apparatuur (elektrische apparatuur en niet-elektrische apparatuur). <\/p>\n\n<h3 class=\"wp-block-heading\">Wat zijn de voorwaarden voor een explosie in een ATEX-zone?<\/h3>\n\n<p>Een ATEX-explosie wordt geactiveerd wanneer 6 omstandigheden tegelijkertijd optreden.<\/p>\n\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>3 elementen in voldoende hoeveelheid om <strong>de ATEX te ontsteken<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Brandbaar product<\/strong> (gas, damp, stof) aanwezig in de atmosfeer van het gebied<\/li>\n\n\n\n<li><strong>Verbrandingsmiddel<\/strong> (zuurstof uit de atmosfeer) dat de verbranding stimuleert van brandstof die aanwezig is in de atmosfeer van de zone<\/li>\n\n\n\n<li><strong>Ontstekingsbron<\/strong> (bijv. elektrische vonk) die voldoende energie levert om de explosieve atmosfeer te ontsteken.<\/li>\n<\/ol>\n\n\n\n<p>3 verbrandingsversnellers om ontsteking om te zetten in explosie<\/p>\n\n\n\n<ol class=\"wp-block-list\" start=\"4\">\n<li>Homogeen zuurstofmengsel &#8211; brandbaar product (gas\/damp\/stof) in explosiegevaarlijke omgeving<\/li>\n\n\n\n<li>In de ATEX bevindt de concentratie van het brandbare product zich binnen het explosieve bereik.<\/li>\n\n\n\n<li>Voldoende insluiting om de <strong>juiste druk<\/strong> te verkrijgen om de verbranding te versnellen<\/li>\n<\/ol>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/conditions-dexplosition-atex.png\" alt=\"atex bedrijfsomstandigheden\" class=\"wp-image-19050\" width=\"350\" height=\"300\" srcset=\"https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/conditions-dexplosition-atex.png 350w, https:\/\/obera.fr\/wp-content\/uploads\/2023\/02\/conditions-dexplosition-atex-300x257.png 300w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/figure>\n<\/div>\n<\/div>\n\n<h3 class=\"wp-block-heading\">Wat is het mechanisme achter een ATEX-explosie?<\/h3>\n\n<p>Een ATEX komt in contact met een ontstekingsbron.<strong>Er ontstaat<\/strong> een<strong>explosie<\/strong>: onmiddellijke verbranding van de brandbare producten in de ATEX, waarbij intense energie vrijkomt. De explosie neemt de vorm aan van een<strong>plotselinge toename van het volume, de druk en de temperatuur van de gassen<\/strong> in de ATEX. Dit veroorzaakt een overdrukgolf die zich voortplant met een snelheid van 2 tot 10 km\/s (explosie-effect), vlammen en vrijkomende hitte. Een deel van de energie van de explosiegolf verbrijzelt het contactoppervlak of de behuizing waarin de explosieve atmosfeer was opgesloten en werpt vervolgens fragmenten van het verbrijzelde materiaal uit.    <\/p>\n\n<p>De<strong>explosiegolf<\/strong> verplaatst zich dan in concentrische zones aan supersonische snelheid; hij neemt dan geleidelijk af in 2 fasen: een tijd van overdruk (1 tot 5 milliseconden) en een <strong>tijd van depressie<\/strong> (zuiging) tot hij terugkeert naar <strong>de normale atmosferische druk<\/strong> (5 tot 25 ms). De explosiegolf neemt af met de afstand en de mate van insluiting van de atmosfeer in het werkgebied. De afname is: zeer gering wanneer de explosiegolf zich langs \u00e9\u00e9n as voortplant (verbindingskanaal tussen apparaten, enz.), sneller bij een tweedimensionale voortplanting (bedrijfsruimten, enz.), zeer snel in een open omgeving (apparaten buiten de bedrijfsruimten, enz.). Beveiligingssystemen beperken de explosie op verschillende manieren: ontluchting, ontkoppelingssystemen, enz.   <\/p>\n\n<h3 class=\"wp-block-heading\">Wat zijn de risico&#8217;s van ATEX-explosies?<\/h3>\n\n<h4 class=\"wp-block-heading\">ATEX-explosierisico&#8217;s voor de veiligheid van werknemers.<\/h4>\n\n<p>De risico&#8217;s voor werknemers bij een ATEX-explosie vormen de basis van de regelgeving voor hun bescherming en veiligheid. Het <strong>risico op letsel<\/strong> varieert afhankelijk van de zone waarin de werknemer wordt blootgesteld aan het explosiegevaar. <\/p>\n\n<h4 class=\"wp-block-heading\">Risico op letsel door ontploffing :<\/h4>\n\n<ul class=\"wp-block-list\">\n<li>risico&#8217;s doordat de<strong>explosiegolf<\/strong> holle of met gas gevulde lichaamsdelen raakt<\/li>\n\n\n\n<li>risico&#8217;s in verband met de<strong>gevolgen van verwachte fragmenten van<\/strong> ontplofte installaties of apparatuur,<\/li>\n\n\n\n<li>risico dat de werknemer door de explosiegolf wordt geslingerd<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">Risico op verwondingen door de impact van de ATEX-explosie op installaties, apparatuur, materialen enz:<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>risico op brandwonden, verbrijzeling, inademing van giftige stoffen<\/strong>; gevolgen van vernietiging en ontbranding door de explosie<\/li>\n\n\n\n<li>risico&#8217;s voor het <strong>immuunsysteem en het zenuwstelsel <\/strong>door opname van giftige stoffen<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">ATEX-explosierisico&#8217;s voor apparatuur.<\/h4>\n\n<p>De explosiegolf en de ontsteking van de atmosfeer veroorzaken effecten op de apparatuur. De explosie kan <strong>fragmentatie van het bronapparaat veroorzaken<\/strong>, de aanwezigheid van een krater op het epicentrum van de explosie, de projectie van materiaalfragmenten die de apparatuur of infrastructuur doorzeven, de projectie van ontstoken materialen die bronnen zijn van verdere ontstekingen of explosies (domino-effect), enz. <\/p>\n\n<p>Zodra de risico&#8217;s van een ATEX-explosie zijn beoordeeld, moet de werkgever verschillende maatregelen nemen <strong>om de veiligheid<\/strong> en bescherming van werknemers en apparatuur <strong>te garanderen<\/strong>: DRPCE, <strong>beschermingssystemen en -kleding<\/strong>, ATEX-apparatuur, enz.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dit acroniem, afgeleid van Europese richtlijnen, verwijst naar de atmosfeer in een werkgebied waar explosiegevaar bestaat en waar speciale beschermingsnormen nodig zijn voor de veiligheid op het werk. ATEX kan overal voorkomen: binnenin machines of tanks, werkstations, magazijnen, enz. <\/p>\n","protected":false},"author":4,"featured_media":93613,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Hoe helpen ATEX-normen explosies voorkomen?","_seopress_titles_desc":"In dit artikel vind je alle basisbeginselen die je moet weten als je werkt in een ATEX-zone met explosiegevaar.","_seopress_robots_index":"","footnotes":""},"categories":[313],"tags":[121],"class_list":["post-93678","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ons-advies","tag-entete-klein-nl","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","no-featured-image-padding","resize-featured-image"],"acf":[],"_links":{"self":[{"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/posts\/93678","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/comments?post=93678"}],"version-history":[{"count":1,"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/posts\/93678\/revisions"}],"predecessor-version":[{"id":93690,"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/posts\/93678\/revisions\/93690"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/media\/93613"}],"wp:attachment":[{"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/media?parent=93678"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/categories?post=93678"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/obera.fr\/nl\/wp-json\/wp\/v2\/tags?post=93678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}