{"id":40706,"date":"2024-01-02T15:14:02","date_gmt":"2024-01-02T13:14:02","guid":{"rendered":"https:\/\/obera.fr\/non-classifiee\/procesi-i-heqjes-se-pluhurit-dhe-rreziku-i-shperthimit-ose-zjarrit\/"},"modified":"2025-04-15T10:23:18","modified_gmt":"2025-04-15T08:23:18","slug":"procede-depoussierage-risque-explosion-incendie","status":"publish","type":"post","link":"https:\/\/obera.fr\/sq\/keshilla-jone-sq\/procede-depoussierage-risque-explosion-incendie\/","title":{"rendered":"Procesi i heqjes s\u00eb pluhurit dhe rreziku i shp\u00ebrthimit ose zjarrit"},"content":{"rendered":"\n<p><strong>Mbledh\u00ebsit e pluhurit<\/strong> p\u00ebrdoren p\u00ebr t\u00eb parandaluar rreziqet e zjarrit dhe shp\u00ebrthimit n\u00eb proceset industriale q\u00eb pezullojn\u00eb grimcat shum\u00eb t\u00eb im\u00ebta. Por k\u00ebto rreziqe shpesh transferohen n\u00eb sistemin e grumbullimit t\u00eb pluhurit, i cili thith dhe filtron pluhurin e djegsh\u00ebm. Prandaj, <strong>masat parandaluese dhe mbrojt\u00ebse duhet t\u00eb zbatohen edhe n\u00eb sistemin e nxjerrjes s\u00eb pluhurit<\/strong> .  <\/p>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"444\" src=\"https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/16802-1024x444.jpg\" alt=\"Shp&#xEB;rthim  \" class=\"wp-image-27454\" style=\"width:458px;height:auto\" srcset=\"https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/16802-1024x444.jpg 1024w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/16802-300x130.jpg 300w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/16802-768x333.jpg 768w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/16802-1536x666.jpg 1536w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/16802-2048x888.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h2 class=\"wp-block-heading\">Parimet e funksionimit t\u00eb llojeve t\u00eb ndryshme t\u00eb kolektor\u00ebve t\u00eb pluhurit<\/h2>\n\n<p>N\u00eb <strong>pajisjet p\u00ebr heqjen e pluhurit<\/strong> , b\u00ebhet nj\u00eb dallim midis kolektor\u00ebve t\u00eb pluhurit t\u00eb that\u00eb (ciklonet, filtrat e qeseve, filtrat e xhepit ose filtrat e fishek\u00ebve, kolektor\u00ebt elektrostatik\u00eb t\u00eb pluhurit) dhe kolektor\u00ebt e pluhurit t\u00eb lag\u00ebsht.<\/p>\n\n<p><strong>Ciklonet p\u00ebrdorin forc\u00eb centrifugale<\/strong> p\u00ebr t\u00eb ndar\u00eb pluhurin nga ajri q\u00eb e bart at\u00eb. Nga lart posht\u00eb, ato marrin nj\u00eb form\u00eb cilindrike dhe m\u00eb pas t\u00eb cunguar. N\u00eb krye t\u00eb cilindrit t\u00eb sip\u00ebrm \u00ebsht\u00eb hyrja e ajrit me pluhur tangjent me perimetrin e ciklonit. Ajri me pluhur n\u00eb hyrje rrotullohet rreth mureve nd\u00ebrsa zbret, duke u ndar\u00eb nga kokrrat m\u00eb t\u00eb trash\u00eb p\u00ebr shkak t\u00eb gravitetit. Pastaj, p\u00ebrmes qendr\u00ebs s\u00eb ciklonit, ajri ngrihet n\u00eb maj\u00eb ku ndodhet dalja. Pluhuri i trash\u00eb grumbullohet n\u00eb pjes\u00ebn e poshtme t\u00eb konit dhe <strong>zbrazet n\u00ebp\u00ebrmjet nj\u00eb pajisjeje nxjerrjeje<\/strong> (valvul\u00eb e dyfisht\u00eb, bllokim ose valvul rrotullues). N\u00eb dalje, ajri ende p\u00ebrmban pluhurin m\u00eb t\u00eb im\u00ebt, i cili mund t\u00eb hiqet vet\u00ebm nga nj\u00eb grumbullues pluhuri qese ose fishek\u00ebsh.      <\/p>\n\n<p>Nj\u00eb kolektor pluhuri me qese, fishek ose filt\u00ebr xhepi funksionon n\u00eb parimin e nj\u00eb fshes\u00eb me korrent sht\u00ebpiake. \u00c7do m\u00ebng\u00eb filtri, xhep ose fishek ndalon pluhurin n\u00eb sip\u00ebrfaqen e tij dhe lejon q\u00eb ajri pa pluhur t\u00eb kaloj\u00eb. Nj\u00eb kolektor pluhuri p\u00ebrb\u00ebhet nga dy pjes\u00eb: Nj\u00ebra pjes\u00eb merr ajrin me pluhur q\u00eb vjen nga pajisja e grumbullimit t\u00eb pluhurit; M\u00ebng\u00ebt e filtrit mbajn\u00eb pluhurin duke lejuar q\u00eb ajri t\u00eb kaloj\u00eb. Nj\u00eb plesht n\u00eb fund t\u00eb pjes\u00ebs me pluhur do t\u00eb mbledh\u00eb pluhurin e grumbulluar n\u00eb m\u00ebng\u00ebt, i cili do t\u00eb lirohet gjat\u00eb <strong>\u00e7do operacioni t\u00eb zhbllokimit<\/strong> (dridhje, rrym\u00eb ajri i kompresuar). Gryka zbrazet n\u00eb nj\u00eb en\u00eb t\u00eb mbyllur ose n\u00ebp\u00ebrmjet nj\u00eb valvule rrotulluese. N\u00eb pjes\u00ebn tjet\u00ebr, ajri pa pluhur del nga filtri dhe m\u00eb pas drejtohet n\u00eb nj\u00eb kanal n\u00eb t\u00eb cilin nj\u00eb ventilator thith rrjedh\u00ebn e ajrit, p\u00ebr ta nxjerr\u00eb at\u00eb ose p\u00ebr ta futur p\u00ebrs\u00ebri n\u00eb dhom\u00eb.     <\/p>\n\n<p>Nj\u00eb <strong>precipitues elektrostatik<\/strong> (ose precipitues elektrostatik) punon n\u00eb t\u00ebrheqjen e nd\u00ebrsjell\u00eb t\u00eb dy element\u00ebve q\u00eb kan\u00eb nj\u00eb ngarkes\u00eb elektrike t\u00eb kund\u00ebrt. <a href=\"https:\/\/obera.fr\/sq\/produits\/depoussiereurs-industriels\/\">Kolektori industrial i pluhurit ngarkon<\/a> negativisht pluhurin e pezulluar n\u00eb rrjedh\u00ebn e ajrit. Kjo b\u00ebhet duke e kaluar at\u00eb p\u00ebrmes nj\u00eb rrjeti telash me tension shum\u00eb t\u00eb lart\u00eb (anod\u00eb). M\u00eb pas, pluhuri ndahet nga rryma e ajrit duke u t\u00ebrhequr nga mure t\u00eb ngarkuara pozitivisht (katod\u00eb), mbi t\u00eb cilat ngjitet. Pluhuri i grumbulluar m\u00eb pas shk\u00ebputet nga katoda duke <strong>goditur me \u00e7ekan ose duke pastruar me uj\u00eb<\/strong> . Pluhuri mblidhet n\u00eb nj\u00eb plesht.     <\/p>\n\n<p>Nj\u00eb pluhur i lag\u00ebsht detyron rrym\u00ebn e ajrit t\u00eb pluhurosur p\u00ebrmes nj\u00eb kolone uji (flluskuese), ose nj\u00eb perde uji q\u00eb rrjedh ose nj\u00eb mjegull kund\u00ebr rrym\u00ebs me uj\u00eb t\u00eb sp\u00ebrkatur. Pluhuri ngjitet n\u00eb molekulat e ujit dhe ndahet nga ajri. <\/p>\n\n<p><\/p>\n\n<h2 class=\"wp-block-heading\">Rreziku i zjarrit ose shp\u00ebrthimit n\u00eb nj\u00eb sistem grumbullimi t\u00eb pluhurit<\/h2>\n\n<h3 class=\"wp-block-heading\">Rreziku i formimit t\u00eb ATEX<\/h3>\n\n<p>Q\u00eb nj\u00eb <strong>ATEX t\u00eb formohet n\u00eb nj\u00eb ciklon<\/strong> , niveli i pluhurit t\u00eb rrjedh\u00ebs s\u00eb ajrit duhet t\u00eb arrij\u00eb intervalin shp\u00ebrthyes dhe p\u00ebrqindja e grimcave t\u00eb im\u00ebta duhet t\u00eb jet\u00eb e mjaftueshme. Grimcat e m\u00ebdha kan\u00eb nj\u00eb efekt ftoh\u00ebs n\u00eb flak\u00eb dhe parandalojn\u00eb p\u00ebrhapjen e saj kur ato jan\u00eb shum\u00eb t\u00eb bollshme. <\/p>\n\n<p>Rrjedha e ajrit me pluhur q\u00eb kalon p\u00ebrmes kanalit hyn n\u00eb sensorin e ajrit me pluhur n\u00eb trupin e bagazhit dhe mund t\u00eb p\u00ebrb\u00ebj\u00eb nj\u00eb ATEX n\u00ebse p\u00ebrqendrimi i pluhurit n\u00eb rrjedh\u00ebn e ajrit <strong>\u00ebsht\u00eb brenda intervalit shp\u00ebrthyes<\/strong> . N\u00eb k\u00ebt\u00eb rast, ATEX do t\u00eb hyj\u00eb n\u00eb kolektorin e pluhurit.   <\/p>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-1-1024x576.png\" alt=\"Logoja e Atex\" class=\"wp-image-27514\" style=\"width:432px;height:auto\" srcset=\"https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-1-1024x576.png 1024w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-1-300x169.png 300w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-1-768x432.png 768w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-1-1536x864.png 1536w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-1-2048x1152.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>Krijimi i nj\u00eb ATEX mund t\u00eb jet\u00eb i p\u00ebrkohsh\u00ebm. N\u00eb var\u00ebsi t\u00eb procesit, niveli i pluhurit t\u00eb rrjedh\u00ebs s\u00eb ajrit n\u00eb kanal mund t\u00eb ndryshoj\u00eb me kalimin e koh\u00ebs. N\u00eb t\u00eb v\u00ebrtet\u00eb, shkalla e emetimit t\u00eb grimcave t\u00eb djegshme gjat\u00eb funksionimit t\u00eb nj\u00eb pajisjeje mund t\u00eb mos jet\u00eb konstante, ve\u00e7an\u00ebrisht gjat\u00eb fillimit ose mbylljes s\u00eb procesit, operacioneve t\u00eb nd\u00ebrprera, fazave t\u00eb funksionimit, etj. <strong>\u00c7mbyllja pneumatike e m\u00ebng\u00ebve ose fishek\u00ebve<\/strong> n\u00eb p\u00ebrgjith\u00ebsi prodhon nj\u00eb ATEX, grimcat m\u00eb t\u00eb im\u00ebta, m\u00eb tep\u00ebr kur pajisja mbyllet dhe mbyllet m\u00eb shum\u00eb, kur pajisja vihet p\u00ebrs\u00ebri n\u00eb presion. (zhbllokimi n\u00eb fund t\u00eb ciklit).<\/p>\n\n<p>Kur p\u00ebrdorni nj\u00eb kolektor pluhuri t\u00eb lag\u00ebsht p\u00ebr t\u00eb filtruar ajrin e ngarkuar me grimca metalike (ve\u00e7an\u00ebrisht alumini), ekziston rreziku q\u00eb t\u00eb ndodh\u00eb nj\u00eb reaksion kimik midis ujit dhe metalit, duke prodhuar hidrogjen. Natyra e metalit ndikon n\u00eb kinetik\u00ebn e reaksionit dhe gjat\u00eb funksionimit normal t\u00eb kolektorit t\u00eb pluhurit, shkalla e emetimit t\u00eb hidrogjenit \u00ebsht\u00eb e pamjaftueshme. Kur kolektori i pluhurit ndalet, mund t\u00eb ket\u00eb nj\u00eb akumulim t\u00eb hidrogjenit n\u00eb hap\u00ebsir\u00ebn ajrore t\u00eb kolektorit t\u00eb pluhurit, duke gjeneruar nj\u00eb rrezik ATEX. Nga ana tjet\u00ebr, <strong>heqja e pluhurit t\u00eb lag\u00ebsht<\/strong> n\u00eb p\u00ebrgjith\u00ebsi mbetet parimi m\u00eb i sigurt i heqjes s\u00eb pluhurit nga pik\u00ebpamja ATEX, pasi burimet e ndezjes n\u00eb p\u00ebrgjith\u00ebsi shuhen nga veprimi i ujit.   <\/p>\n\n<h3 class=\"wp-block-heading\">Rreziku i ndezjes dhe shp\u00ebrthimit t\u00eb ATEX<\/h3>\n\n<p>Kalimi i rrjedh\u00ebs s\u00eb ajrit me pluhur n\u00eb kanal i n\u00ebnshtrohet dukuris\u00eb s\u00eb ngarkimit elektrostatik t\u00eb pluhurit nga f\u00ebrkimi i tij n\u00eb mur. Ky fenomen mund t\u00eb jet\u00eb i pranish\u00ebm edhe n\u00eb pjes\u00ebn me pluhur t\u00eb grumbulluesve t\u00eb pluhurit. Shkarkimi elektrostatik mund t\u00eb jet\u00eb i mundur n\u00eb tubacion ose n\u00eb nj\u00eb kolektor pluhuri. Energjia q\u00eb l\u00ebshon vler\u00ebsohet n\u00eb m\u00eb pak se 10 mJ. N\u00ebse kjo energji e \u00e7liruar tejkalon energjin\u00eb minimale t\u00eb ndezjes s\u00eb pluhurit t\u00eb varur, <strong>shkarkimi elektrostatik do t\u00eb jet\u00eb burimi i tyre i ndezjes<\/strong> , pra shp\u00ebrthimi i ATEX n\u00eb tubacion ose n\u00eb pjes\u00ebn me pluhur t\u00eb nj\u00eb kolektori pluhuri me qese.    <\/p>\n\n<p>Precipituesi elektrostatik punon n\u00eb ndryshimin e potencialit midis anod\u00ebs dhe katod\u00ebs. P\u00ebr shkak t\u00eb intensitetit t\u00eb k\u00ebtij ndryshimi, distanca midis elektrodave duhet t\u00eb rregullohet p\u00ebr t\u00eb shmangur formimin e nj\u00eb harku elektrik (prishje), nj\u00eb burim ndezjeje n\u00eb nj\u00eb ATEX. <\/p>\n\n<p>Nj\u00eb proces mund t\u00eb l\u00ebshoj\u00eb pluhur dhe grimca inkandeshente (shtypje, bluarje, etj.). K\u00ebto mund t\u00eb jen\u00eb nj\u00eb burim ndezjeje i nj\u00eb ATEX t\u00eb pranish\u00ebm n\u00eb pjes\u00ebn me pluhur ose n\u00eb <strong>m\u00ebng\u00ebt e filtrit t\u00eb nj\u00eb kolektori pluhuri<\/strong> . N\u00eb k\u00ebt\u00eb rast, n\u00eb p\u00ebrgjith\u00ebsi do t\u00eb preferohet nj\u00eb zgjidhje p\u00ebr heqjen e pluhurit t\u00eb lag\u00ebsht ose nj\u00eb zgjidhje e that\u00eb p\u00ebr heqjen e pluhurit me para-ndarje t\u00eb shk\u00ebndijave dhe nj\u00eb pajisje p\u00ebr zbulimin dhe shuarjen e shk\u00ebndijave.  <\/p>\n\n<h3 class=\"wp-block-heading\">Rrezik zjarri<\/h3>\n\n<p>Studimet e aksidenteve tregojn\u00eb se nj\u00eb <strong>shp\u00ebrthim n\u00eb nj\u00eb kolektor pluhuri n\u00eb qese<\/strong> shpesh pasohet nga nj\u00eb zjarr i pluhurit t\u00eb depozituar n\u00eb fund t\u00eb pleshtit dhe n\u00eb filt\u00ebr, dhe p\u00ebr rrjedhoj\u00eb edhe t\u00eb vet\u00eb filtrit.  <\/p>\n\n<p>Filtrimi i ajrit me pluhur nuk prodhon ngrohjen e pluhurit. Prandaj nuk ka rrezik zjarri n\u00eb kolektor\u00ebt e pluhurit t\u00eb filtrit p\u00ebr shkak t\u00eb vet\u00eb-ngrohjes, me p\u00ebrjashtim t\u00eb rasteve t\u00eb ve\u00e7anta kur <strong>substancat e kapura n\u00eb temperatur\u00ebn e dhom\u00ebs<\/strong> kan\u00eb nj\u00eb v\u00ebllim kritik vet\u00eb-nxeh\u00ebs. Kur v\u00ebllimi n\u00eb fund t\u00eb filtrit e kalon k\u00ebt\u00eb, rreziku i zjarrit b\u00ebhet i duksh\u00ebm.  <\/p>\n\n<h2 class=\"wp-block-heading\">Masat p\u00ebr parandalimin dhe mbrojtjen e rrezikut ATEX p\u00ebr grumbulluesit e pluhurit.<\/h2>\n\n<h3 class=\"wp-block-heading\">Masat parandaluese sipas llojit t\u00eb grumbulluesve t\u00eb pluhurit<\/h3>\n\n<p>Masa p\u00ebr parandalimin e <a href=\"https:\/\/obera.fr\/sq\/keshilla-jone-sq\/procedes-industriels-prevention-risques-explosion-depoussiereurs-industriels\/\">zjarrit dhe shp\u00ebrthimit<\/a> p\u00ebr kolektor\u00ebt e pluhurit t\u00eb qeseve konsiston n\u00eb shtypjen e shkarkimeve elektrostatike duke p\u00ebrdorur qese antistatike. Megjithat\u00eb, statistikat e aksidenteve raportojn\u00eb se mos tok\u00ebzimi i k\u00ebtyre llojeve t\u00eb filtrave mund t\u00eb \u00e7oj\u00eb n\u00eb <strong>shkarkime elektrostatike q\u00eb tejkalojn\u00eb energjin\u00eb minimale t\u00eb ndezjes<\/strong> s\u00eb pluhurave t\u00eb zakonsh\u00ebm. Ky mosfunksionim do t\u00eb \u00e7onte n\u00eb nj\u00eb rrezik m\u00eb t\u00eb madh se ai i filtrave t\u00eb qeseve jo antistatike.  <\/p>\n\n<p>N\u00eb rastin e nj\u00eb grumbulluesi pluhuri qese, monitorimi i rregullt i konsumimit, shk\u00ebputjes ose shpimit t\u00eb qeseve \u00ebsht\u00eb pjes\u00eb e parandalimit ATEX. Kontrollimi i presioneve hyr\u00ebse\/dal\u00ebse dhe instalimi i nj\u00eb opacimetri n\u00eb zon\u00ebn pa pluhur mund\u00ebson <strong>kontrollimin e ngusht\u00ebsis\u00eb s\u00eb rrjedhjeve t\u00eb m\u00ebng\u00ebve.<\/strong> <\/p>\n\n<p>P\u00ebr t\u00eb parandaluar rreziqet elektrostatike nga shkaktimi i ndezjes, pjes\u00ebt metalike t\u00eb kolektorit t\u00eb pluhurit t\u00eb qeseve duhet t\u00eb tok\u00ebzohen, duke p\u00ebrfshir\u00eb tubat. E nj\u00ebjta gj\u00eb vlen edhe p\u00ebr ciklonin. Komponent\u00ebt elektrik\u00eb brenda kolektorit t\u00eb pluhurit duhet gjithashtu t\u00eb jen\u00eb n\u00eb p\u00ebrputhje me rregulloret ATEX.    <\/p>\n\n<p>Nj\u00eb nga masat parandaluese kund\u00ebr grimcave inkandeshente \u00ebsht\u00eb instalimi i nj\u00eb parandar\u00ebsi pluhuri p\u00ebrpara kolektorit kryesor t\u00eb pluhurit, qoft\u00eb n\u00eb form\u00ebn e nj\u00eb cikloni, nj\u00eb ndar\u00ebs ndikimi ose nj\u00eb pajisje <strong>p\u00ebr zbulimin dhe shuarjen e shk\u00ebndijave<\/strong> .<\/p>\n\n<p>N\u00eb rastin e nj\u00eb kolektori elektrostatik pluhuri, kontrolli i rregullt i cil\u00ebsimit t\u00eb diferenc\u00ebs potenciale dhe distanc\u00ebs nd\u00ebrmjet elektrodave do t\u00eb parandaloj\u00eb rrezikun e harkut elektrik.<\/p>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-2-1024x576.png\" alt=\"dustomat hidro 2\" class=\"wp-image-27518\" style=\"width:441px;height:auto\" srcset=\"https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-2-1024x576.png 1024w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-2-300x169.png 300w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-2-768x432.png 768w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-2-1536x864.png 1536w, https:\/\/obera.fr\/wp-content\/uploads\/2024\/01\/dustomat-hydro-2-2048x1152.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p><strong>Parandalimi i shp\u00ebrthimit ATEX<\/strong> n\u00eb kolektor\u00ebt e pluhurit t\u00eb tipit t\u00eb lag\u00ebsht konsiston n\u00eb: ventilimin e v\u00ebllimit t\u00eb tij kur ai ndalet p\u00ebr t\u00eb shmangur grumbullimin e hidrogjenit, zbulimin e hidrogjenit n\u00eb tavanin e kolektorit t\u00eb pluhurit. Ky lloj kolektori pluhuri duhet t\u00eb instalohet jasht\u00eb p\u00ebr t\u00eb holluar pranin\u00eb e hidrogjenit, ose n\u00eb nj\u00eb dhom\u00eb t\u00eb pajisur me ventilim specifik p\u00ebr t\u00eb parandaluar shp\u00ebrthimet. Nj\u00eb rrezik zjarri mund t\u00eb lind\u00eb nga rezistor\u00ebt e ngrohjes q\u00eb synojn\u00eb t\u00eb mbrojn\u00eb kolektorin e pluhurit t\u00eb lag\u00ebsht nga ngrirja. Zhytja e k\u00ebtyre rezistor\u00ebve duhet t\u00eb kontrollohet.   <\/p>\n\n<p><\/p>\n\n<h3 class=\"wp-block-heading\">Masat mbrojt\u00ebse<\/h3>\n\n<p>Masat mbrojt\u00ebse kan\u00eb t\u00eb b\u00ebjn\u00eb:  <\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>Pajisjet e ajrosjes s\u00eb shp\u00ebrthimit t\u00eb kolektorit t\u00eb pluhurit<\/strong> : pjes\u00eb e murit t\u00eb kolektorit t\u00eb pluhurit, q\u00eb hapet n\u00eb fillimin e presionit t\u00eb tep\u00ebrt q\u00eb rezulton nga shp\u00ebrthimi i brendsh\u00ebm i ATEX, p\u00ebr t\u00eb evakuuar gazrat dhe presionin e tep\u00ebrt.<\/li>\n\n\n\n<li><strong>P\u00ebrdorimi i shtyp\u00ebsve t\u00eb shp\u00ebrthimit<\/strong> : pajisje q\u00eb zbulon fillimin e shp\u00ebrthimit brenda kolektorit t\u00eb pluhurit, parandalon shp\u00ebrthimin t\u00eb arrij\u00eb presionin maksimal t\u00eb tij duke injektuar nj\u00eb produkt shuarjeje, duke mbrojtur muret e kolektorit t\u00eb pluhurit nga plasja  <\/li>\n\n\n\n<li><strong>Shk\u00ebputja e kolektorit t\u00eb pluhurit<\/strong> nga pjesa tjet\u00ebr e instalimit p\u00ebr t\u00eb parandaluar p\u00ebrhapjen e shp\u00ebrthimit n\u00eb kolektorin e pluhurit n\u00eb tuba. Kjo p\u00ebrfshin instalimin e nj\u00eb valvule n\u00eb tubacionet q\u00eb lidhin kolektorin e pluhurit, i cili mbyllet automatikisht n\u00ebn efektin e val\u00ebs s\u00eb presionit (valvula e kthimit ATEX ose valvula mbyll\u00ebse e shpejt\u00eb). <\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Mbledh\u00ebsit e pluhurit p\u00ebrdoren p\u00ebr t\u00eb parandaluar rreziqet e zjarrit dhe shp\u00ebrthimit n\u00eb proceset industriale q\u00eb pezullojn\u00eb grimcat shum\u00eb t\u00eb im\u00ebta. Por k\u00ebto rreziqe shpesh transferohen n\u00eb sistemin e grumbullimit t\u00eb pluhurit, i cili thith dhe filtron pluhurin e djegsh\u00ebm. Prandaj, masat parandaluese dhe mbrojt\u00ebse duhet t\u00eb zbatohen edhe n\u00eb sistemin e nxjerrjes s\u00eb pluhurit.  <\/p>\n","protected":false},"author":4,"featured_media":81594,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Procesi i heqjes s\u00eb pluhurit dhe rreziku i shp\u00ebrthimit ose zjarrit","_seopress_titles_desc":"Shmangni rrezikun e shp\u00ebrthimeve dhe zjarrit fal\u00eb procesit t\u00eb heqjes s\u00eb pluhurit. P\u00ebrmbushni standardet e siguris\u00eb dhe rregulloret e pun\u00ebs. ","_seopress_robots_index":"","footnotes":""},"categories":[312],"tags":[116],"class_list":["post-40706","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-keshilla-jone-sq","tag-koka-e-vogel","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","no-featured-image-padding","resize-featured-image"],"acf":[],"_links":{"self":[{"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/posts\/40706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/comments?post=40706"}],"version-history":[{"count":3,"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/posts\/40706\/revisions"}],"predecessor-version":[{"id":82216,"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/posts\/40706\/revisions\/82216"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/media\/81594"}],"wp:attachment":[{"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/media?parent=40706"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/categories?post=40706"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/obera.fr\/sq\/wp-json\/wp\/v2\/tags?post=40706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}